Skip to content
The Automation Partnership

The Automation Partnership

Automated NGS Library Preparation System – Aurora Biomed

  • Home
  • PCR Products
  • Aurora Biotech
  • Privacy Policy
  • Distributors
  • Contact Us
The Automation Partnership

Tag: diagnostics center of america

Centrifuge-free dispersive liquid-liquid microextraction coupled with thin-film microextraction for the preconcentration of molinate in real samples by ion mobility spectrometry

February 13, 2022 Lieven Leave a comment
A tandem microextraction method, centrifuge free dispersive liquid-liquid microextraction and thin-film microextraction (DLLME-TFME), was used for analyzing molinate in environmental samples by ion mobility spectrometry (IMS). Considering the IMS as a competitive detection system, coupling these two popular sample preparation methods reduces the effect of solvent interference and improves the sensitivity of the technique.
Trichloromethane and methanol were used as the extraction, and dispersive solvents for the DLLME method and electrospun polyacrylonitrile/copper-benzene-1,4-dicarboxylic acid fibers were used as a sorbent in the TFME method. Some effective experimental variables influencing the extraction efficiency of an analyte such as type and volume of dispersive and extraction solvents, solution pH, ionic strength, sonication time, and extraction time were studied.
The linear dynamic range of 0.5-50 μg L-1 and the limit of detection of 0.1 μg L-1 were obtained under optimized conditions. The relative standard deviations for intra-and inter-day analysis https://biodas.org/ were calculated less than 10%. The present method was used for the determination of molinate in different real samples such as agricultural wastewater, well water, river water, and apple, and the recovery was obtained between 82% and 113%, for the spiked samples.
Acoustofluidic centrifuge for nanoparticle enrichment and separation

Liquid droplets have been studied for decades and have recently experienced renewed attention as a simplified model for numerous fascinating physical phenomena occurring on size scales from the cell nucleus to stellar black holes. Here, we present an acoustofluidic centrifugation technique that leverages an entanglement of acoustic wave actuation and the spin of a fluidic droplet to enable nanoparticle enrichment and separation.
By combining acoustic streaming and droplet spinning, rapid (<1 min) nanoparticle concentration and size-based separation are achieved with a resolution sufficient to identify and isolate exosome subpopulations.
The underlying physical mechanisms have been characterized both numerically and experimentally, and the ability to process biological samples (including DNA segments and exosome subpopulations) has been successfully demonstrated. Together, this acoustofluidic centrifuge overcomes existing limitations in the manipulation of nanoscale (<100 nm) bioparticles and can be valuable for various applications in the fields of biology, chemistry, engineering, material science, and medicine.

Quantitative Evaluation of a Telerobotic System for Vascular Ultrasound Measurement on a Short Arm Human Centrifuge

  • Artificial Gravity generated by Short Arm Human Centrifuges is a promising multi-system countermeasure for physiological deconditioning during long duration space flights. To allow a continuous assessment of cardiovascular hemodynamics during centrifugation, a telerobotic robotic system holding an ultrasound probe has been installed on a Short Arm Human Centrifuge.
  • A feasibility study was conducted to define the use capabilities and limitations of such a novel method. The objective of this study is to estimate the reproducibility and precision of remotely controlled vascular ultrasound assessment under centrifugation by assessing peripheral vascular diameter and wall distension. Four repeated centrifugation runs of 5 min, with 2.4 g at feet level, were performed including a 15 min rest between each run for a group of eight healthy male volunteers. Vascular diameter and distention were assessed for the common carotid artery (CCA) and the femoral artery (FA) by ultrasound imaging using a 10 MHz linear array probe (Mylab1, Esaote).
  • Ultrasound measurements were consecutively performed: a) by an expert user in hand-held mode in standing as well as supine position, b) using the telerobotic arm without centrifugation as baseline and c) using the telerobotic arm during centrifugation. Vascular responses were compared between baseline and under centrifugation. Inter-, intra-registration and group variability have been assessed for hand-held and remotely controlled examination.
  • The results show that intra-registration variability, σ h , was always smaller than inter-registration variability, σ m, that is in turned smaller than the inter-subject variability σ g (σ h < σ m < σ g). Centrifugation caused no significant changes in CCA diameter but a lower carotid distension compared to manual and robotic ultrasound in supine position (p < 0.05). Femoral diameter was significantly decreased in hypergravity compared to robotic sonography without centrifugation.
  • A good reproducibility and precision of the remotely controlled vascular ultrasound assessment under centrifugation could be demonstrated. In conclusion, arterial wall dynamics can be precisely assessed for the CCA and femoral artery during centrifugation using a telerobotic ultrasound measurement system. Potential improvements to further enhance reproducibility and safety of the system are discussed.

Assessment of bridge natural frequency as an indicator of scour using centrifuge modelling

One of the most prevalent causes of bridge failure around the world is “scour”-the gradual erosion of soil around a bridge foundation due to fast-flowing water. A reliable technique for monitoring scour would help bridge engineers take timely countermeasures to safeguard against failure. Although vibration-based techniques for monitoring structural damage have had limited success, primarily due to insufficient sensitivity, these have tended to focus on the detection of local damage. High natural frequency sensitivity has recently been reported for scour damage.
Previous experiments to investigate this have been limited as a result of the cost of full-scale testing and the fact that scaled-down soil-structure models tested outside a centrifuge do not adequately simulate full-scale behaviour. This paper describes the development of what is believed to be the first-ever centrifuge-testing programme to establish the sensitivity of bridge natural frequency to scour. A 1/60 scale model of a two-span integral bridge with 15 m spans was tested at varying levels of scour. For the fundamental mode of vibration, these tests found up to a 40% variation in natural frequency for 30% loss of embedment.
Models of three other types of foundation, which represent a shallow pad foundation, a deep pile bent and a deep monopile, were also tested in the centrifuge at different scour levels. The shallow foundation model showed lower frequency sensitivity to scour than the deep foundation models. Another important finding is that the frequency sensitivity to “global scour” is slightly higher than the sensitivity to “local scour”, for all foundation types. The level of frequency sensitivity (3.1-44% per scour depth equivalent to 30% of embedment of scour) detected in this experiment demonstrates the potential for using natural frequency as an indicator of both local and global scour of bridges, particularly those with deep foundations.

Microliter ultrafast centrifuge platform for size-based particle and cell separation and extraction using novel omnidirectional spiral surface acoustic waves

Asymmetric surface acoustic waves have been shown useful in separating particles and cells in many microfluidics designs, mostly notably sessile microdroplets. However, no one has successfully extracted target particles or cells for later use from such samples. We present a novel omnidirectional spiral surface acoustic wave (OSSAW) design that exploits a new cut of lithium niobate, 152 Y-rotated, to rapidly rotate a microliter sessile drop to ∼10 g, producing efficient multi-size particle separation.
We further extract the separated particles for the first time, demonstrating the ability to target specific particles, for example, platelets from mouse blood for further integrated point-of-care diagnostics. Within ∼5 s of surface acoustic wave actuation, particles with diameter of 5 μm and 1 μm can be separated into two portions with a purity of 83% and 97%, respectively.
Red blood cells and platelets within mouse blood are further demonstrated to be separated with a purity of 93% and 84%, respectively. These advancements potentially provide an effective platform for whole blood separation and point-of-care diagnostics without need for micro or nanoscale fluidic enclosures.
Product not found
  • HIV-1 genotypic resistance testing using the Vela automated next-generation sequencing platform
  • Sample Quality Control of Cell-Free DNA
https://youtu.be/ojYHnZZbwz8

Join Our Newsletter

Subscribe our newsletter to receive the latest news.

Check your inbox or spam folder to confirm your subscription.

Microfluidics NewsFollow

Provides daily update on everything about microfluidics news: research paper, conferences, protocols and more.

Microfluidics News
Retweet on TwitterMicrofluidics News Retweeted
natBMENature Biomedical Engineering@natBME·
18 May 2020

A fidget spinner for the point-of-care diagnosis of urinary tract infection

https://rdcu.be/b4fh8

2
Reply on Twitter 1262425643788251136Retweet on Twitter 126242564378825113651Like on Twitter 1262425643788251136162Twitter 1262425643788251136
Retweet on TwitterMicrofluidics News Retweeted
HHMINEWSHHMI NEWS@HHMINEWS·
29 Mar 2019

“We’ve discovered a new way the gut talks to the brain." http://bit.ly/2OC3qIo

Reply on Twitter 1111766736162951175Retweet on Twitter 111176673616295117513Like on Twitter 111176673616295117526Twitter 1111766736162951175
Retweet on TwitterMicrofluidics News Retweeted
uFluidixuFluidix Inc.@uFluidix·
16 Jan 2019

🚀The Prototyping Grant 2019 is now open! Developing a novel product with a #microfluidic component in it? receive free prototyping services from @uFluidix. Eligible microfluidics #startups & #inventors are encouraged to apply! ➡️ http://bit.ly/PrototypingGrant2019

#PrototypingGrant2019

Reply on Twitter 1085552569785729024Retweet on Twitter 108555256978572902473Like on Twitter 108555256978572902476Twitter 1085552569785729024
ufluidics_newsMicrofluidics News@ufluidics_news·
25 Sep 2017

[Scientific Reports] Modelling and Realization of a Water-Gated Field Effect Transistor (WG-FET) Using 16-nm-...
https://www.microfluidics-news.com/single-post/2017/09/25/Scientific-Reports-Modelling-and-Realization-of-a-Water-Gated-Field-Effect-Transistor-WG-FET-Using-16-nm-Thick-Mono-Si-Film

Reply on Twitter 912453841458798594Retweet on Twitter 9124538414587985943Like on Twitter 9124538414587985949Twitter 912453841458798594
ufluidics_newsMicrofluidics News@ufluidics_news·
25 Sep 2017

[Cell Systems] High-Throughput Microfluidic Labyrinth for the Label-free Isolation of Circulating Tumor Cells
https://www.microfluidics-news.com/single-post/2017/09/25/Cell-Systems-High-Throughput-Microfluidic-Labyrinth-for-the-Label-free-Isolation-of-Circulating-Tumor-Cells

Reply on Twitter 912453791747854336Retweet on Twitter 9124537917478543365Like on Twitter 9124537917478543367Twitter 912453791747854336
Load More...

Recent Posts

  • Prediction of Loss of Muscle Mass in Sarcopenia Using Ultrasonic Diaphragm Excursion
  • Centrifuge-free dispersive liquid-liquid microextraction coupled with thin-film microextraction for the preconcentration of molinate in real samples by ion mobility spectrometry
  • Droplet Magnetofluidic Assay Platform for Quantitative Methylation-Specific PCR
  • Superhydrophobic paper in the development of disposable labware and lab-on-paper devices.
  • Lanthanide luminescent nanocomposite for non-invasive temperature monitoring in vivo
Powered by WordPress and Dynamic News.